- New
Inverter Single-phase charger Luxpower Eco hybrid SNA2-EU-LT 10K 10.0kw with BackUp
The inverter Single-phase charger Luxpower Eco hybrid SNA2-EU-LT 10K 10.0kw is an advanced industrial and residential energy management system designed to take the limit photovoltaic performance in own consumption and isolated facilities
LuxPower SNA2-EU-LT 10K: 10KW power, 18KW double MPPT and backrest UPS Critic in less than 10ms
The search for total energy independence and the integral protection of large-scale domestic or commercial consumption find their definitive solution in the new generation of inverters chargers. The LuxPower Hybrid Eco SNA2-EU-LT 10K it is consolidated as one of the most powerful and versatile single-phase options of the current photovoltaic sector
18KW massive photovoltaic entrance with double MPPT and load to 250A
The most outstanding technical aspect of this inverter charger 10.0kw it is its imposing power stage in continuous current
In the storage section, this team works with accumulators Ion-lithium or lead-acid of 48V or 51.2V
Switching UPS Ultravelop, smart generator port and scalability
Reliability in the continuity of electricity supply is an absolute priority in this model. Facing Falls or Blackouts in the Conventional Distribution Network, the LuxPower SNA2-EU-LT 10K switches for backup in a record time less than 10 milliseconds (
This inverter charger also stands out for its exceptional connectivity and peripheral management. It has a separated generator port (gene) that allows the integration of a generator set with automatic start and stop
Technical characteristics:
- Nominal output power AC (network): 10000 W
. - Nominal output power in back mode (UPS): 10000 W
. - Nominal AC voltage Operation: 230 VAC (Single-phase, Range 130-280V)
. - Nominal output current CA: 43.5
. - Maximum PV input power (CC): 18000 W (Distributed in 9000W / 9000W)
. - Number of independent MPPT: 2 MPPT
. - MPPT Work Voltage Range: 120 VDC at 440 VDC
. - Maximum voltage of photovoltaic input (VOC): 480 VDC
. - Solar circuit boot voltage: 100 VDC
. - Maximum PV input current per MPPT: 26 a (Short circuit intensity 32.5)
. - Battery compatibility: Ion-lithium / lead-acid
. - Nominal voltage of the battery bank: 48 V / 51.2 V
. - Maximum loading / unloading current: 250 a
. - Maximum load power / battery discharge: 11000 W
. - Switching time in backup mode (UPS):
. - Dedicated generator port (gene): 15000 W of maximum input (230V / 65A)
. - Maximum efficiency Inverter / MPPT efficiency: 93.5% / 99.0%
. - Electrical protections: Overvoltage, overcurrent, short in AC, network monitoring and overvoltage protection DC / AC type III
. - Interfaces and communications: Screen LCD + RGB, ports RS485, Wi-Fi and Can
. - Dimensions of the chassis: 520 mm wide x 580 mm high x 163 mm depth
. - Structural net weight: 32.5 kg
. - Environmental protection index: Ip20 (Recommended installation indoors or technical rooms)
.
Frequently Asked Questions section (FAQ)
- What advantages does it provide that this inverter charger admits up to 18000W in solar? It allows to ovenex dime the field of
by 180% compared to the power output power (10kw)solar . . This is crucial to ensure that, during the most unfavorable days of the year, with very covered skies or at the extreme hours of dawn and sunset, the plates continue to capture enough energy to cover the house consumption of the house and simultaneously upload the 10000W Bench of batteries at great speed . - What does it mean that the switching time is less than 10 milliseconds? Means that if an unforeseen cut occurs in the outer electric network, the inverter charger changes its supply source towards batteries and solar in less than 10 ms
. . Being such a fast process, it acts as a system UPS or SAI pure sine wave, avoiding computer equipment, servers, routers or domotic systems suffer microcortes, off or data losses . - Why is a 250A load and unloading current as relevant in batteries? A stream of 250a it allows to move massive energy flows (up to 11000W) between the inverter and the 48V battery bank
. This means that you can recharge lithium batteries from large capacity in a very short time when there are full solar surpluses, and at the same time, the system can extract a great accumulated power to feed high consumption appliances without the need for support from the network. - How does the automatic management of the separate generator port (gene) work? The LuxPower SNA2-EU-LT 10K has an exclusive AC input channel for generators
. . This port has signal contacts to order the automatic start and stop generator . . If the battery bank is on a critically low level after several days of rain and there is no available electric network, the inverter start the engine, cover the household consumption, recharge the batteries and turn it off automatically at the end . - Can multiple computers be connected if in the future I need to change to a three-phase network? Yes, it is totally viable. The team is prepared for a professional scalability, allowing parallelf up to 16 units ease
. . This allows you to increase the single-phase power in the same home or interlace the inverters of three in three to generate a network unbalanced three-phase, where a master team centrally manages communication and the distribution of phases of the entire installation .
- Power (kW)
- 10 - 14.9
- Phase Type
- Single phase
- MPPT
- 2
- Inverter Type
- Not hybrid