The 6 mm² unifilar solar cable 6 mm² in black It is the DC driver designed specifically for the wiring of photovoltaic installations, from the panel chains until the inverter or the regulator. Manufactured according to the European Standard In 50618, he supports a Nominal voltage of 1500 V DC (1.0 kV AC), suitable for residential and commercial installations. His driver of Class 5 flexible tinned copper (84 yarns of 0.283 mm) facilitates the laying and resists corrosion, while the Double isolation of XLPE (Isolation and crosslinked cover) gives you great resistance to the weather: UV, ozone, acid and alkalis rays. Is a cable Free of halogens and low emission of fumes, he works between -40 and +90 ° C With a maximum driver temperature of 120 ° C, it admits 70 a in the air and has a 24-year-old service life. It is supplied in Roll of 500 m.

The minimum purchase order quantity for the product is 10.

 

Detailed technical characteristics

General data

  • Cable type: H1Z2Z2-K, unifilar (1 x 6 mm²)
  • Manufacturing Standard: EN 50618: 2014
  • Cover color: black
  • Format: roll of 500 m
  • Application: internal wiring of solar panels and photovoltaic installations
  • Marking of the cover: EC, H1Z2Z2-K, 1.0 kV AC / 1.5 KV DC, halogen-free and low smoke emission

Construction

  • Nominal section: 6 mm²
  • Driver: tinker, class 5 (flexible) according to IEC 60228
  • Driver's training: 84 yarns of 0.283 mm
  • Diameter of the driver: 3,02 mm
  • Insulation material: XLPE (cross-linked polyethylene)
  • Insulation thickness (medium / minimum:) 0.7 / 0.53 mm
  • Diameter on isolation: 4.60 mm
  • Cover material: XLPE
  • Cover thickness (medium / minimum:) 0.8 / 0.58 mm
  • External diameter of the cable: 6.4 mm

Electrical characteristics

  • Nominal voltage: 1500 V DC (1.0 kv AC)
  • Test voltage: 6.5 kV BC, 50 Hz, 5 min
  • DC tension test of isolation: 1800 V, 240 h (85 ° C, 3% NaCl) without drilling
  • Maximum driver resistance at 20 ° C: 3.39/km
  • Minimum insulation resistance at 20 ° C: 499 MΩ · km
  • Minimum insulation resistance at 90 ° C: 0,499 MΩ · km

Admissible intensity (atmosphere 60 ° C, Driver max 120 ° C)

  • Unique cable outdoors: 70 A
  • Unique cable on surface: 67 A
  • Two cables in contact on surface: 57 A

Terms of use

  • Working temperature: -40 to +90 ° C
  • Short circuit temperature: 250 ° C for 5 s
  • Minimum curvature radius: 6 x outside diameter
  • Lifetime: 25 years or more
  • Thermal resistance: TI 120 (EN 60216-1 / 2)

Material tests

  • Resistance to UV rays: EN 50289-4-17
  • Ozone resistance: IN 50396
  • Acid resistance and alkalis: EN 60811-2-1
  • Low temperature impact (-40 ° C, 5 h:) EN 60811-1-4
  • Behavior against fire: IEC 60332-1-2
  • Halogen content: according to IN 50618
  • COVER CONTRACTION: 2 % o less (EN 60811-503)

Benefits of Solar Cable H1Z2Z2-K 6 mm² black

Designed for the weather for decades

The wiring of a photovoltaic installation spends years exposed to the sun, to rain and great changes in temperature. The double isolation of Reticulated XLPE of the H1Z2Z2-K is rehearsed in front of uV, ozone, acid and alkalis rays and supports impacts to -40 ° C, which explains his 24-year-old service life, in line with that of the panels themselves.

6 mm²: less losses in long runs

With a maximum resistance of 3.39/km, the 6 mm² section reduces tension falls against 4 mm² cables, something especially important in long runs between the solar field and the inverter or with the high currents of the solar panels high-power Less drop in tension means more energy exploited.

1500 V DC for any configuration

Its nominal tension of 1500 V DC covers with margin the chains of the inverters solar residential and commercial, including equipment three-phase who work with String tensions of up to 1000 or 1100 V.

Safer in case of fire

Being free of halogens and low emission of fumes, in case of fire does not release corrosive gases or dense and toxic smoke, and their behavior against the flame is tested according to IEC 60332-1-2. It is a relevant feature in housing covers, ships and public buildings.

Copper tinned and flexible

The driver of class 5 with 84 tinned copper wires it is flexible, easy to tend by trays and tubes, and better resists oxidation than naked copper, which maintains the quality of connections with the MC4 terminals over time.

How to use the black cable in your installation

Identification of the negative pole

In photovoltaic installations, the black cable for the negative pole and the red for the positive. Separating both colors facilitates assembly, avoids polarity errors and simplifies revisions and maintenance.

Laying and radius of curvature

Respects a minimum curvature radius of 6 times the outside diameter; with 6.4 mm in diameter, it is equivalent to some 38 mm as a guidance calculation. Fix the cable to the structures for solar panels avoiding sharp edges and mechanical tensions.

Roll of 500 m for installers

The format of 500 m it is designed for installers and for projects with several large solar installations or fields, reducing splices and waste of material.

Complement your installation with solar kits complete or with the rest of the components you will find in Tienda Solar. In the Blog Tienda Solar you have guides on how to size the wiring of your installation, prepared by experts.

Frequently Asked Questions (FAQ)

1. What does H1Z2Z2-K MEAN?

Is the normalized designation of the cables for photovoltaic systems according to the IN 50618. Indicates a harmonized cable, with isolation and cover of halogen-free reticulated compound and flexible conductor (K, suitable for 1500 V DC.

2. When to use 6 mm² instead of 4 mm²?

The section 6 mm² it is recommended in long runs, with high currents or when you want to limit the voltage drop below the target of the installation. The calculation of the section must do the installer according to the length, the current and the applicable regulations.

3. What current does the 6 mm² cable support?

According to the manufacturer 60 ° C of room temperature, , 70 A with a unique cable to the air, 67 A on surface and 57 A with two cables in contact on surface.

4. Can you install buried or under tube?

The cable is designed for the wiring of photovoltaic installations and can lie on tray or under tube. For buried installations, always follows what indicates the current regulations (for example, tube channeling) and the criteria of the designer.

5. What connectors do I need?

To join the cable to the panels and inverter type connectors are used MC4 compatible with sections of 6 mm². Check that the chosen connector supports this section.

6. How long does the cable last?

The manufacturer indicates a 24-year-old service life, with a working temperature of -40 to +90 ° C and resistance to UV, ozone and chemical agents.