The power counter Victron ET340 (Rel300300000) It is a meter three-phase of direct measurement up to 65 a per phase, manufactured by Carlo Gavazzi to Victron, designed to integrate with the GX devices and the systems ESS three-phase of Victron. Installed at the connection point, acts as network counter and measures phase to phase imported and exported energy, so that the system can manage self-consumption, battery charge and pouring control in the three phases. It also serves to measure the exit of a inverter Fv three-phase, from a generator or of AC loads, and even to measure independently net inverter FV in a single-phase installation. Offers Class 1 precision in active energy according to EN 62053-21 and ± 0.5% reading in current and tension, with an update rate of 2000 ms. Occupies 3 DIN modules, it is communicated by Rs485 and your data is displayed in the GX and in the Portal VRM.
Detailed technical characteristics
- Reference Victron: Rel300300000
- Model Carlo Gavazzi: Et340-din.av23.x.s1.x
- Number of phases: 3
- Nominal maximum current: 65 a per phase
- Type of measurement: Direct (Direct / Shunt)
- Active energy precision: Class 1 according to EN 62053-21
- Current precision and tension: ± 0.5% reading
- Communication: Rs485
- Update rate: 2000 ms
- Screen: not (Communication indication LED)
- Assembly: DIN rail, 3 modules
- Energy Registration: arithmetic
- Compatibility: GX devices Victron with Venus OS, Portal VRM
- Connection to the GX: RS485 cable, RS485 interface to USB or converters ZigBee
- Applications: Network counter ESS three-phase, inverter Fv three-phase, generator, charges, combined measurement Red + FV in single-phase installations
- System manufacturer: Victron Energy, with quality system ISO 9001: 2015 (TÜV NORD, valid up to 2027)
Benefits of the Energy Counter Victron Et340
Control phase to phase in ESS systems three-phase
In a home or business with supply three-phase, each phase may be importing or exporting energy differently. The ET340 measures the three phases separately and sends that data to the GX device, which coordinates the inverters-Barkers and the lithium batteries To optimize self-consumption in the set of installation.
65 a per phase without transformers
The direct measurement up 65 a per phase Covers most supplies three-phase Residential and small trade without the need to install current transformers, which simplifies the assembly in the box.
A counter for two single-phase measurements
In facilities single-phase with a inverter FV that must be measured, the ET340 can replace two ET112: one of its phases measures the network and another production of the inverter, Saving space and a second accountant.
Class 1 precision
With Class 1 in active energy according to EN 62053-21 and ± 0.5% Reading in current and tension, the system has reliable data to make your control decisions.
Compact format of 3 DIN modules
It is installed in the DIN Rail of the box occupying alone 3 modules, and your data is consulted on the GX device and on the VRM portal, from anywhere.
Installation and election of the counter
Single-phase or three-phase
Victron recommends a counter three-phase like the ET340 for a Three-phase connection to the network or to measure a inverter Fv three-phase, and an accountant single-phase like Et112 For single-phase connections.
If you overcome 65 a per phase
For currents superior to 65 a per phase, Victron Recommend counters with Current transformers.
Communication with the GX
It connects Rs485, normally with the interface Victron RS485 to USBor wirelessly with converters ZigBee. Keep in mind that many inverters solar They offer direct reading in the system Victron, without a counter to measure your production.
Find inverters hybrid, solar panels and Solar kits to complete your system in Tienda Solar, and consult the Blog Tienda Solar For technical guides prepared by experts.
Frequently Asked Questions (FAQ)
1. What is the counter used for? Victron Et340?
Like network counter in systems ESS three-phase of Victron and to measure inverters Fv three-phase, generators or AC loads. Also allows measuring net inverter Fv In a single-phase installation.
2. What maximum current does it measure?
Until 65 a per phase in direct measurement. For older currents, a counter with current transformers is needed.
3. Can I use it in a single-phase installation?
Yes. Victron Indicates that, in a single-phase installation with a inverter FV that must be measured, can be used Two Et112 or an ET340.
4. What is the difference with ET112?
The Et112 it is single-phase until 100 a and it is updated each 750 ms; the Et340 it is three-phase until 65 a per phase and it is updated each 2000 ms. Neither has a screen.
5. How is it connected to the GX device?
For Rs485, through the interface Victron RS485 to USB or wireless converters ZigBee of Victron.
6. How much space occupies in the box?
Occupies 3 DIN modules.