Inverter Three-phase solar for self-consumption or network connection SMA of 5000W AC with 2 MPPT with 97.4% efficiency and maximum 12A input current per inlet with convection cooling. The Sunny Tripower stands out for its variety of configurations, wide MPPT voltage range and its lightweight and compact structure.
The Sunny Tripower have short-circuit protection, overloads and high temperatures, will provide a problem-free operation in its three-phase solar installation for many years. Inverter Solar for solar installations with excellent value for money. The Sunny Tripower line does not include transformer, in addition to offering a degree of protection.
Warranty of 5 years of product.
The inverters sunny Sunny Tripower Solar stand out for the following characteristics:
- - Inverter solar lightweight (17kg) which allows you to manage by one person
- - Compact design inverter to occupy less space
- - Easy installation with the Plug & Play system
- - Intelligent management and energy storage solutions can be added at any time
- - It can be combined with the TS4-R components to optimize the module
- - Use of excess energy by dynamic limitation of active power
- - Shadow Management with Optitra Global Peak or Integrated TS4-R

|
Model |
Sunny Tripower 5.0 |
|
Max power. Ad |
9000 W |
|
Voltage Max. Entrance |
850 V |
|
Range Voltage MPP |
215V to 800 V |
|
Voltage Nominal Entrance |
580 V |
|
Min. Voltage Entrance / Voltage Initial Entrance |
125 V / 150 V |
|
Max current. Entry: Entrance to / input B |
12 a / 12 a |
|
Max. Current Entry by String: Input A / Input B |
18 a / 18 a |
|
Number of independent entries MPP Input / Strings by entry MPP |
2 / A: 1; B: 1 |
|
OUTPUT (AC) |
|
|
Power (at 230 V, 50Hz) |
5000 W |
|
Max. Apparent power AC |
5000 VA |
|
Nominal Voltage AC / Range |
3 / no / PE; 220 V / 380 V 3 / no / PE; 230 V / 400 V 3 / no / PE; 240 V / 415 V |
|
AC Frequency / Range |
50 Hz, 60 Hz / -5 Hz to +5 Hz |
|
Nominal frequency / nominal voltage |
50 Hz / 45 Hz to 55 Hz 60 Hz / 55 Hz to 65 Hz |
|
Max current. Exit |
3 x 7.6 A |
|
Power factor at nominal power |
1 |
|
Power factor setting |
+/- 0.8 |
|
FASHINGSCARING / FASESCONNECTION |
3/3 |
|
Eficienciamax. Efficiency |
98.2% / 97.4% |
|
Protection elements |
|
|
Internal disconnection point |
● |
|
Earthing monitoring / Network monitoring |
● / ● |
|
Reverse polarization protection in DC / Short circuit capacity AC / Galvanic isolation |
● / ● / - |
|
Residual-polle-sensitive monitoring unit |
● |
|
Protection Type (IEC 62103) / SOVERVALEE CATEGORY (based on IEC 60664-1) |
I / III |
|
Datosgenerales |
|
|
Dimensions (width / high / long) |
435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) |
|
Weight |
17 kg (37.4 lbs) |
|
Operating temperature range |
-25 ° C to + 60 ° C (-13 ° F to + 140 ° F) |
|
Emission, typically |
30 dB (a) |
|
Self-consumption (night) |
5.0 w |
|
Topology |
Transformer |
|
Type of cooling |
Convection |
|
Degree of protection (based on IEC 60529) |
Ip65 |
|
Climate category (based on IEC 60721-3-4) |
4k4h |
|
Max value. allowed for relative humidity (without condensing) |
100% |
|
Teams |
|
|
Connection / Connection |
Sunclix / AC connector |
|
View on Smartphone, Tablet, Laptop |
● |
|
Interface: WLAN, Ethernet / RS485 |
● / ● / ● |
|
Warranty: 5/10 / 15 years |
● / ○ / ○ |
|
Certificates and approvals (more available upon request) |
AS 4777, C10 / 11, CE, CEI 0-21, DIN EN 62109-1 / IEC 62109-1, DIN EN 62109-2 / IEC 62109-2, EN 50438, G59 / 3, G83 / 2, NEN-EN 50438, ÖVE / ÖNORM E 8001-4-712, PPDS, PPC, RD 1699, SI 4777, TR 3.2.1, UTE C15-712, VDe-AR-N 4105, VDE-0126-1-1, VFR 2014 |
|
Certificates and Approvals |
DEWA 2016, EN 62116, IEC 61727, IE-EN 50438, NBR 16149, NRS 097-2-1 |
|
Availability of SMA Smart Connected in countries |
Au, at, be, ch de, es, it, lu, nl, uk |
|
Reference |
Stp5.0-3av-40 |
- Power (kW)
- 3 - 5.9
- Phase Type
- Three-phase
- Max Current Input (A)
- 12 - 12.99