The inverter Charger Voltonic Axpert MKS 3K-48 Plus delivery 3000VA / 3000W nominal power with pure sinusoidal wave and Power factor 1, on a bank of battery 48v and with a POWER OF PICO OF 6000VA To absorb refrigeration starts, pumps or tools. Integrate a MPPT Solar Regulator admitted 3000W photovoltaic field, with a tracking range of 60 to 115 VDC, maximum tension in open circuit 145 VDC, 60A solar load current and one Maximum efficiency of 98%. Your network loader or generator is selectable to 10a or 15a, with a Total load current of up to 75A, and the priority between Solar Fountain and Network is configured from the LCD Display, with Optional remote panel For your remote control. With a Single 2W rest consumption, it is a compact solution for Isolated single-phase facilities at 230V.
Detailed technical characteristics
Power and output
- Model: Axpert MKS 3K-48 Plus
- Nominal power: 3000VA / 3000W
- POWER OF PICO (SURGE:) 6000VA
- Tension regulation AC (Battery mode:) 230VAC ± 5%
- Waveform: Pure sinusoidal wave
- Output power factor: 1
- Efficiency (peak:) 90% - 93%
- Transfer time: 10 ms (personal computers) / 20 ms (electronics)
Entrance
- Input voltage: 230 VAC
- Selectable voltage range: 170-280 VAC (personal computers) / 90-280 VAC (electronics)
- Frequency range: 50 Hz / 60 Hz (automatic detection)
Drums
- Battery voltage: 48 VDC
- Load voltage in flotation: 54 VDC
- Protection against overload: 62 VDC
Solar charger and charger AC
- Type of regulator: MPPT integrated
- Maximum power of the FV field: 3000 W
- MPPT range at operating voltage: 60 - 115 VDC
- Maximum tension in open circuit (VOC:) 145 VDC
- Maximum current of solar load: 60 A
- Maximum load current CA: 10 A.m.-15 a (selectable)
- Maximum total load current: AT
- Maximum MPPT efficiency: 98%
- Sabbath: 2 W
Physical data and surroundings
- Dimensions (F x an x al:) 140 x 295 x 479 mm
- Net weight: 11.5 kg
- Humidity: 5% to 95% of relative humidity (without condensation)
- Operating temperature: 0 ° C to 55 ° C
- Storage temperature: -15 ° C at 60 ° C
Benefits of the Voltronic Axpert MKS 3K-48 Plus
The range Axpert Voltronic Power is one of the most widespread references in isolated network facilities, and the version MKS PLUS concentrate on a single team the three basic functions of an off-grid system: inverter pure wave, MPPT solar regulator and battery charger from network or generator set. This reduces wiring, flaw points and space in the technical room in front of riding inverter and regulator separately.
The differential data against other equipment in its rank is the power factor 1: the 3000Va nominal equals 3000W real, without the 80% reduction that many present inverters of entrance To this adds a 6000vA overload, enough for the start of compressor motors and small pumps.
Work 48V it also has practical advantages: for the same power, the current on the continuous side is half that in a 24V system, which allows cable sections more contained and lower losses between the bank of lithium batteries or lead and the inverter.
In the Solar section, the MPPT with 98% efficiency take full advantage of the production of solar panels, and his vacuum consumption of Solo 2W it prevents the team itself from downloading the battery during the night or in periods without consumption, something especially relevant in intermittent housing.
For what facilities are you indicated?
Second residences, booths and orchards
Its power 3kw covers lighting, refrigerator, small appliances, television, router and low power water pumps, with the tranquility of being able to connect a generator as backup in weeks of low radiation.
Support in housing with unstable supply
Thanks to the AC entrance with selectable range and a transfer time of 10 ms in computer mode, you can act as a backup power system for computer equipment and critical charges.
Solar Solar Kits Compact
It is a habitual basis of the solar kits small and medium power off-grid, combined with a 48V battery bank and a FV field of up 3000W.
Keys to size the photovoltaic field
The regulator MKS 3K-48 Plus is an MPPT low: he works between 60 and 115 VDC and it does not admit more than 145 VDC in open circuit. In practice, this forces to design short strings (normally two modules in series with standard power panels) and connect several strings in parallel until reaching the desired power. It is essential to calculate the VOC at the minimum temperature of the site, since in winter the tension of the modules increases. Remembers also that the solar load current is limited to 60A, so it overthrees the field above 3000W it does not provide more energy to the battery. To fix the modules, review our structures for solar panels.
On Tienda Solar we help you square the series-parallel settings with the panel model you choose, and in the Blog Tienda Solar you will find purchase guides and technical items prepared by experts to design your isolated installation step by step.
Frequently Asked Questions (FAQ)
1. Is the Axpert MKS 3K-48 PLUS runs without batteries?
It is not the planned configuration. It is a inverter off-grid charger designed to work with a battery bank 48V, which is the one that stabilizes the system and stores solar energy for night use.
2. What batteries can I connect?
Admits banks of 48V of lead, as aGM batteries or gel batteries, with floating voltage of 54 VDC. If you opt for lithium, it is convenient to check that the load parameters of the inverter they are compatible with the values required by the BMS of the battery.
3. How many solar panels can I connect in series?
Depends on the VOC of the module. With a maximum tension of entry 145 VDC, the usual with standard power panels is to connect 2 modules in series by string, always checking the tension at the minimum expected temperature.
4. Can I connect a generator to load the batteries?
Yes. The team is compatible with electrical network or generator set, with a load current CA selectable 10A or 15A, and allows you to configure the priority between the solar source and the AC source from the LCD.
5. What is the difference between the 60As of the MPPT and the maximum loading 75A?
The 60A they are the maximum current that the solar regulator provides. The 75A they are the total maximum load current, which is reached by adding the solar contribution and that of the AC charger when both sources are available.
6. Is it a hybrid inverter of injection to network?
No. is a team off-grid that can take power from the network to feed loads or load batteries, but do not pour surpluses. If you are looking for self-consumption connected to network with batteries, consult our inverters hybrid.
- Power (kW)
- 3 - 5.9
- Phase Type
- Single phase