The hybrid inverter SAJ Hs2-6k-s2 It is the most powerful model of the HS2 series single-phase: a team all in one of 6 kW gathering inverter photovoltaic, battery management and backup output in a stackable tower, supplied in this pack with the Chint DDSU666 meter and its 100 A power transformer. Admits 9000 WP solar field 2 MPPT of 16 a, so the high-powered panels take full advantage. Delivery 6000 W to a network with a nominal current of 26.1 a, and in back mode it keeps 6000 continuously with peaks 7200 goes for 60 s, commute to 10 ms or less. Work with batteries LifePo4 from 85 to 450 V and 30 a loading and unloading, enlarges with up 4 BU2-5.0 modules until 20 kwh. With 97.6% efficiency, Ip65 and compliance with RD 1699, RD 413, UNE 206006/206007 and NTS, is designed for housing with high consumption.

 

Detailed technical characteristics

Photovoltaic entrance (DC)

  • Maximum FV power: 9000 WP (STC)
  • Maximum DC voltage: 550 V
  • MPPT voltage range: 90 to 500 V
  • Nominal DC voltage: 360 V
  • Starting voltage: 100 V
  • MPPT number: 2
  • Maximum entry DC current: 16/16 A
  • Maximum DC short stream: 19.2 / 19.2 A

Drums

  • Type: Lifepo4
  • Battery voltage range: 85 to 450 V
  • Maximum loading / unloading current: 30/30
  • Extension: BU2-5.0-HV1 / 5, up 4 modules

AC output network

  • Nominal AC power: 6000 W
  • Maximum apparent power: 6000
  • Nominal output current (230 Vac:) 26.1 A
  • Maximum output current: 27.3 A
  • Start current (INRUSH:) 100 A
  • Maximum current of AC: 55 A
  • Maximum overcurrent protection AC: 55 A
  • Voltage / range: L + N + PE, 220/230/240 V; 180 to 280 V
  • Frequency / range: 50/60 Hz; 45-55 / 55-65 Hz
  • Power factor: 0.8 capacitive to 0.8 inductive
  • Thdi: less than 3%

AC input from Network

  • Voltage / range: L + N + PE, 220/230/240 V; 180 to 280 V
  • Nominal frequency: 50/60 Hz
  • Maximum input current (230 VAC:) 52.2 A

Backup output (back-up)

  • Maximum output power: 6000
  • Maximum output current: 27.3 A
  • Apparent Power of Peak: 7200 Goes for 60 s
  • THDV (Linear Load:) less than 3%
  • Switching time UPS: 10 ms or less

Efficiency

  • Maximum efficiency: 97.6%
  • European efficiency: 97.0%

Protections

  • Reverse battery polarity, overload and short AC: integrated
  • DC and AC overvoltages: integrated
  • Anti-island: integrated
  • AFCI and RSD: optional

Interface and general data

  • Connections: MC4 / H4 (FV,), plug-in connector (AC,), fast connector (battery)
  • Screen: LED + APP
  • Communication: Wi-Fi / Ethernet / 4G (optional)
  • Topology: transformer
  • Operating temperature: -10 at +50 ° C (reduction above 45 ° C)
  • Refrigeration: natural convection
  • Altitude: 4000 m (reduction above 3000 m)
  • Noise: less than 35 DBA
  • Degree of protection: IP65
  • Dimensions (at x an x PR:) 354 x 626 x 365 mm
  • Weight: 25 kg
  • Warranty: 5/10 / 15/20 (according to option)
  • Rules: EN 62109-1 / 2, EN 61000-6-2 / 4, EN 50438, EN 50549, C10 / 11, IEC 62116, IEC 61727, RD 1699, RD 413, UNE 206006, UNE 206007, NTS, CEI 0-16, CEI 0-21, AS 4777.2, NBR 16149, NBR 16150, VDE-AR-N 4105, VDE 0126-1-1

Pack content

  • 1 hybrid inverter SAJ HS2-6K-S2
  • 1 chint DDSU666 Energy Meter
  • 1 current transformer (CT) of 100 A

Benefits Hybrid Inverter SAJ HS2-6K-S2

The maximum power of the HS2 series single-phase

With 6000 W nominal, the HS2-6K-S2 is the option of the housing range with aerotermia, air conditioning, induction plate or electric vehicle recharge, where models 3 to 5 kW are short. Its maximum current of entry from Network 52.2 A it also allows charging the battery and feeding the house at a time without restrictions.

9000 WP of Solar Field in Two Guidelines

The inverter admits a 150% of oversized photovoltaic, up 9000 WP, scattered in 2 MPPT independent 16 A. This allows you to combine two roof skirts with different orientations and take advantage of solar panels of great format without losses by current limitation.

Back of 6 kVA for all housing

In case of blackout, the backup output delivery 6000 continuous 7200 Goes from peak for 60 s, enough to hold the main circuits of the house and absorb the starting of pumps or compressors. Switching in 10 ms or less avoid restarts in most electronic equipment.

Stackable tower with batteries SAJ

The modules BU2-5.0 they are stacked under the inverter forming a single set of 626 x 365 mm of plant You can start with a module and grow up 20 kwh of lithium batteries, a capacity according to the power of the equipment.

Intelligent self-consumption management with chint ddsu666

The included meter registers in real time the energy imported and exported at the connection point. With that information, the inverter decides when to load the battery, when to download it and how limit if the installation requires it. The current transformer 100 A it is installed by hugging the driver, without cuts.

When to choose the SAJ HS2-6K-S2

Comparative with the HS2-5K-S2

In front of the 5 kW model, the HS2-6K-S2 rises the maximum FV power of 7500 a 9000 WP, the nominal power of 5000 to 6000 W and the peak of backup 6000 to 7200 VA, maintaining the same size, weight and battery compatibility. It is the logical choice if the housing consumption usually exceeds 5 kW or if it is expected to expand consumption in the future.

Contracted power and legalization

A inverter of 6 kW single-phase it fits into most Spanish residential supplies. Its certification according to NTS and RD 1699 it facilitates the processing of the installation of self-consumption with the distributor.

Complete your installation

For assembly of the solar field arrange structures for solar panels coplanar, inclined and soil, and if you prefer a closed system, check our solar kits or the rest of inverters hybrid.

On Tienda Solar we help you dimension your system, and in the Blog Tienda Solar you will find purchase guides and technical items prepared by experts.

Frequently Asked Questions (FAQ)

1. What is the difference between HS2-6K-S2 and HS2-5K-S2?

Both share the housing, weight (25 kg) and compatible batteries. The HS2-6K-S2 offers 6000 W nominal in front of 5000 W, admits 9000 WP of panels versus 7500 WP and its backrest peak reaches 7200 VA facing 6000 VA.

2. How much battery can I install?

Until 4 modules BU2-5.0-HV1 / 5, stacked under the inverter, which allows to reach 20 kwh storage.

3. What can I feed during a light cut?

The backup delivery delivery 6000 continuous 7200 Goes for 60 s. It is enough for the essential circuits of a home (lighting, refrigerator, router, pumps or boiler), provided that the battery has charge.

4. Is the Chint DDSU666 meter necessary?

Yes, to work in self-consumption mode. The meter reports to the inverter of the energy that comes in and leaves the network, which allows it prioritize self-consumption, load the battery with surplus and apply zero injection when necessary.

5. Can I connect panels on two roofs with different orientations?

Yes. The inverter has 2 MPPT independent with 16 A and a range of 90 to 500 V each one, so each orientation works at its optimal point.

6. Do you make noise?

No. It is cooled by natural convection, without fans, and his sound level is less than 35 dba.

Power (kW)
6 - 9.9
Phase Type
Single phase
MPPT
2
Inverter Type
Hybrid