- New
The hybrid Inverter Hoymiles Hys-10.0lv-eug2 belongs to the new generation of single-phase equipment of the HYS-LV-EUG2 series, with a Nominal power of 10000 W Designed for installations of residential self-consumption and small commercial facilities with a high consumption. Has Double Follower MPPT up 32 a per entrance, which supports a recommended FV power of up 13000 W Thanks to its DC / AC ratio up to the 130%, Ideal to maximize production in oversized installations. Your EMS system automatically manages self-consumption, economic modes and backUp, and switches to back mode in less than 10 ms, offering practically instant supply continuity. It is compatible with lithium and lead-acid batteries in a range of 40 to 60 V, it reaches a maximum efficiency of the 97,6% and has a degree of protection Ip65 that allows its installation both indoors and outdoors.
Benefits Hybrid Inverter Hoymiles Hys-10.0lv-eug2
With a Nominal power of 10000 W and a recommended FV power up 13000 W, HYS-10.0LV-EUG2 is designed for housing with a high electricity consumption or for small businesses seeking to maximize their self-consumption. Its DC / AC ratio of up to 130% Allows you to install more generation power from the usual without oversizing the inverter, taking full advantage of the production of solar panels Even in the hours of lower irradiance of the day.
The Double Follower MPPT, with 32 a of current per input and capacity for up to 4 strings, it provides design flexibility in roofs with different orientations or partial shades. At storage level, this inverter it is compatible with lithium batteries and lead-acid in a range of 40 to 60 V, with communication Can and automatic adaptation to the BMS, which expands the options available within the catalog of lithium batteries of Tienda Solar To design custom storage systems.
Intelligent Energy Management (EMS) and BackUp
The EMS system of HYS-10.0LV-EUG2 allows you to select between self-consumption mode, to prioritize the direct use of solar energy; economic mode, which optimizes the load and unloading cycles of the battery according to the schedule of electricity; and mode backUp, which ensures the supply of all the house or the selected critical charges before a network cut. Your backup switch acts on less than 10 ms, so the transition is practically imperceptible to connected equipment. In addition, it incorporates Intelligent export limitation a Network and a configurable dry contact as a ground failure alarm, load control or an auxiliary generator control.
Design, installation and monitoring
With a weight of 41 kg and a degree of protection Ip65, the HYS-10.0LV-EUG2 is installed on the wall both indoors and abroad, without the need for additional protection cabinets. Can be combined in parallel with up 10 units For higher power installations, and its monitoring is managed remotely through S-Miles Cloud, allowing installers and end users to review solar production in real time, battery status and performance historic. It is a suitable option to give the jump of a Solar Kit basic to a system with backUp Real and higher power available.
Detailed technical characteristics
Drums
- Type of compatible battery: Li-ion / lead-acid
- Battery voltage range: 40-60 V
- Maximum loading / unloading current: 200/200
- Maximum loading / unloading power: 10000/10000 W
- Load strategy for Li-ion batteries: AutoAdaptation to BMS
- Cargo curve: 3 stages / equalization
- External temperature sensor: Optional
- Communication with battery: Can
Photovoltaic entrance (FV)
- Maximum recommended FV power: 13000 W
- Maximum input voltage: 550 V
- Nominal voltage: 360 V
- Starting voltage: 150 V
- MPPT voltage range: 125-500 V
- Maximum input current: 32/32
- Maximum short circuit: 40/40
- Number of MPPT / maximum Strings: 2 MPPT / 4 Strings
AC output (network connection)
- Nominal output power: 10000 W
- Maximum apparent output power: 11000 VA
- Maximum entry power: 23000 W
- Nominal output voltage / Range: 220/230 V, 154-276 V
- Nominal network frequency: 50/60 Hz
- Maximum output current: 47.8 a
- Maximum input current: 100 a
- Power factor: Greater than 0.99 (0.8 in advance ... 0.8 in delay)
- THDI (at nominal power): Lower than 3%
Output AC (Mode BackUp / Off-grid)
- Nominal output power: 10000 W
- Maximum apparent output power: 20000 goes for 10 s
- Switching time backUp: Less than 10 ms
- Nominal output voltage: 220/230 V
- Nominal output frequency: 50/60 Hz
- Maximum continuous output current: 43.5 a
- THDV (with linear load): Lower than 3%
Efficiency
- MPPT efficiency: 99,9%
- Maximum efficiency: 97,6%
- European efficiency (EU): 97,0%
- Maximum efficiency of battery discharge to AC: 95,0%
Protections
- Anti-Isla Protection: Integrated
- Reverse polarity protection in FV input: Integrated
- Detection of insulation resistance: Integrated
- Residual current monitoring: Integrated
- Overcurrent protection AC: Integrated
- Short circuit protection: Integrated
- Overvoltage and Substation protection AC: Integrated
- Overvoltage protection (arises): DC Type II / AC Type III
General characteristics
- Dimensions (an × FO): 502 × 740 × 202 mm
- Weight: 41 kg
- Assembly: Mural (wall)
- Operating temperature: -25 ° C A + 65 ° C (derating from 45 ° C)
- Relative humidity: 0-95%, without condensation
- Refrigeration: Smart Cooling
- Topology (Solar / Battery): No transformer / high frequency insulation
- Maximum altitude: ≤2000 m
- Degree of protection: Ip65
- Noise level: Less than 40 dB
- User interface: LED and app
- Digital Tickets / Outputs: 1 × di, 2 × do
- Maximum in parallel: 10 units
- Communication: RS485, Wi-Fi / Ethernet / 4G (optional)
Certifications and regulations
- Network connection regulations: EN 50549, NRS 097-2-1
- Security regulations / EMC: IEC 62109-1 / -2, IEC / EN 61000-6-1 / -2 / -3 / -4
Frequently Asked Questions (FAQ)
1. What power of Can I install with the HYS-10.0LV-EUG2? Thanks to its DC / AC ratio up to the 130%, this inverter Supports a recommended FV power up 13000 W, distributed among his 2 MPPT Followers and a maximum of 4 Strings of solar panels.
2. What batteries can I connect to this hybrid Inverter? The HYS-10.0LV-EUG2 supports lithium batteries and lead-acid in a range of voltage 40 to 60 V, with communication Can and self-authentication to the BMS, allowing us to combine it with most market storage solutions.
3. How long does it take to activate the mode backUp before a supply cut? The switching time as backUp is lower than 10 ms, so that connected equipment barely noticed the transition, protecting both sensitive appliances and critical household charges.
4. Is this apt inverter for outdoor installation? Yes. Your degree of protection Ip65 It allows to install it abroad with exposure to dust and water jets, always within its operating temperature range of -25 ° C A + 65 ° C, without the need for additional cabinets.
5. How many inverters HYS-10.0LV-EUG2 can be combined in the same installation? This model admits 10 units in parallel, which allows you to scale the total power of the system for installations with a particularly high consumption, maintaining centralized monitoring through S-Miles Cloud and the range of inverters hybrid of Hoymiles.
If you have doubts about what hybrid Inverter best suits your installation, in Tienda Solar we have a specialized catalog, and in our Blog Tienda Solar You will find purchase, comparative and technical content guides prepared by our team of Solar Energy Experts.
- Power (kW)
- 10 - 14.9
- Phase Type
- Single phase
- MPPT
- 2
- Inverter Type
- Hybrid