Solar Inverter SMA Sunny Tripower STP15000TL-30 (WITHOUT DISPLAY)
Three-phase solar inverter for self-consumption or grid connection from SMA 15000W AC with 2 MPPT with 98% efficiency and a maximum input current of 33 A per input with OptiCool cooling system. The Sunny Tripower line stands out for its cost-effectiveness, safety, extensive flexibility and new power management features.
The Sunny Tripower inverter line is protected against short circuits, overloads and high temperatures and will provide trouble-free operation of your three-phase solar system for many years. Grid-connected inverter for solar systems with an excellent price/performance ratio. Does not include transformer and offers IP65 protection.
Product warranty of 5 years.
The solar inverters of the Sunny Tripower family are characterized by the following features:
- - Maximum efficiency of 98.4 %.
- - Integrated DC surge arrester (DPS type II)
- - DC input voltage up to 1000 V
- - Perfect system design thanks to the multistring concept
- - Innovative network management functions thanks to Integrated Plant Control
- - 24-hour reactive power supply (Q on Demand 24/7)
Model
|
Sunny Tripower 15000TL
|
Input (CC)
|
|
Max power. DC
|
15330 W
|
Max voltage. Entrance
|
1000V
|
MPP Voltage Range
|
240 V to 800 V/600 V
|
Min/start input voltage
|
150 V/188 V
|
Max current. Input A / Input B
|
33A / 33A
|
Number of independent MPP inputs / strings per MPP input
|
2 / A:3; B:3
|
Output (AC)
|
|
Power (at 230 V, 50Hz)
|
15000W
|
Max. apparent AC power
|
15000 VA
|
Ac rated voltage
|
3/N/PE; 220 V / 380 V
3/N/PE; 230 V / 400 V
3/N/PE; 240 V / 415 V
|
AC voltage range
|
180V to 280V
|
AC network frequency/ range
|
50 Hz / 45 Hz to 55 Hz
60 Hz / 55 Hz to 65 Hz
|
Assigned mains frequency / assigned mains voltage
|
50Hz / 230V
|
Max output current / output assigned current
|
29 A / 21.7 A
|
Power factor to assigned power / Adjustable lag factor
|
1 / 0 inductive to or capacitive
|
THD
|
≤ 3%
|
Injection / connection phase
|
3 /3
|
EfficiencyMax. / European Efficiency
|
98.4% / 98%
|
Protective elements
|
|
Internal disconnect point
|
●
|
Grounding/network monitoring
|
● / ●
|
DC Surge Charger: DPS Type II
|
○
|
Reverse polarization protection in DC / AC short circuit capability / galvanic isolation
|
● / ● / -
|
Residual All-pole-sensitive monitoring unit
|
●
|
Protection class (IEC 62109-1) /voltage category (IEC 62109-1)
|
I/ AC:III;DC:II
|
General Data
|
|
Dimensions (width / height / length)
|
661 mm / 682 mm / 264 mm (26.0 / 26.9 / 10.4 inches)
|
Weight
|
61 kg (134.48 lbs)
|
Operating Temperature Range
|
\u201225°C to +60°C (\u201213°F to +140°F)
|
Emisiónruido, typically
|
51 dB(A)
|
Self-consumption (night)
|
1 W
|
Topology
|
No transformer
|
Cooling type
|
OptiCool
|
Degree of protection (based on IEC 60529)
|
IP65
|
Climate category (based on IEC 60721-3-4)
|
4K4H
|
Max value. allowed for relative humidity (non-condensing)
|
100%
|
Equipment
|
|
ConnectionDC / ConnectionAC
|
SUNCLIX / Spring Connection Edge
|
Screen
|
○
|
Interface: RS485, Speedwire/Webconnect
|
○ / ●
|
Data Interface: SMA Modbus / SunSpec Modbus
|
● / ●
|
Multifunction Relay/Power Control Module
|
○ / ○
|
OptiTrack Global Peak/Integrated Plant Control/Q on Demand 24/7
|
● / ● / ●
|
Compatible with isolated networks/with SMA Fuel Save Controller
|
● / ●
|
Warranty: 5 / 10 / 15 years
|
● / ○ / ○
|
Certificates and approvals
|
ANRE 30, AS 4777, BDEW 2008, C10/11:2012, CE, CEI 0-16, CEI 0-21, EN 50438:2013*, G59/3, IEC 60068-2-x, IEC 61727, IEC 62109-1/2, IEC 62116, NBR 16149, NEN EN 50438, NRS 097-2-1, PPC, RD 1699/413, RD 661/2007, Res. n°7:2013, SI4777, TOR D4, TR 3.2.2, UTE C15-712-1, VDE 0126-1-1, VDE-AR-N 4105, VFR 2014
|
Reference
|
STP 15000TL-30
|
- Power (kW)
- 15 - 19.9
- Phase Type
- Three-phase
- Max Current Input (A)
- 20+