- Online only
- On sale!
The Deep Cycle Gel Monobloc Battery Victron 12V 220AH BAT412201100 (Model Victron Gel V220G) stands out for its high 220Ah energy storage capacity in C20 regime and a 12V nominal voltage, which makes it an ideal solution for the configuration of battery banks in solar self-consumption installations Isolated and autonomous systems that require a power supply free of maintenance. This airtight VRLA technology accumulator incorporates a high purity lead-calcium alloy that guarantee an exceptionally low self-discharge rate, allowing prolonged storage periods without the need for constant compensation recharges. Its advanced industrial design replaces traditional terminals by copper plane terminals with M8 pins, optimizing electrical contact and eliminating the need for additional accessories.
Victron Gel V220G: Hight-a-skilled monobloc storage for self-consumption systems
The deployment of an isolated photovoltaic system or a residential backup network requires electrochemical components capable of supporting recurring deep discharges without compromising their integrity. The deep cycle gel battery Victron Gel V220G it represents the technical reference solution for those seeking stability, operational security and excellent long-term energy retention.
Gelly electrolyte against degradation and copper thermal connectivity M8
Faced with traditional lead-open batteries suffering from acid stratification and water evaporation, this device Victron he confine his electrolyte in the form of a dense gel. This internal structure completely prevents liquid leakage and minimizes internal degradation of the solar panels associated during intense load cycles.
Instead of incorporating the classic conical terminals prone to mechanical wear or to sulfation resistance, this range integrates copper flat terminals for bolts M8. Copper has an electrical conductivity much higher than that of the lead, reducing the voltage drops at the junction points and optimizing the passage of energy towards the inverters of the installation. If you are planning the mechanical assembly of the capture modules on your roof to supply these accumulators, you can guarantee an optimal fixation by reviewing the versatility of the
Minimum rate of self-discharge and flame retardant structural safety
Thanks to the meticulous selection of its cast materials and the use of high purity lead-calcium grids, the Victron Gel V220G offers a extremely low self-discharge rate. This translates into a great energy storage time without the need for recharge, an essential quality for seasonal use housing or second residences that remain inactive during the winter months.
The robustness of the block is backed by a rigid container manufactured in acrylonitrile butadiene styrene (ABS) Fire resistant, strictly complying with international UL and EC security regulations. To keep these blocks loaded efficiently by direct uptake of clean energy in isolated residential environments, many users choose to configure their covers with
Technical characteristics:
-
Commercial model: Victron Gel V220G.
-
Manufacturer's reference: Bat412201100.
-
Nominal capacity: 220 ah in the C20 discharge rate.
-
Nominal system voltage: 12 V.
-
Chemical technology: Gel-up electrolyte of deep cycle (VRLA without maintenance).
-
Electrical connections: Copper flat terminals suitable for m8 bolts.
-
Container material: Rigid Fire Resistant ABS Housing (Flame Retardant).
-
Physical dimensions: 522 mm in length x 238 mm wide x 240 mm tall.
-
Net weight of the block: 66 kg.
-
International Certifications: Compliance with UL and EC regulations.
-
Factory warranty: 2 years of official guarantee Victron with global coverage.
Frequently Asked Questions (FAQ)
- What advantages does the gel technology of this accumulator provide a traditional open-acid battery? The main advantage is that the electrolyte is completely gelled and immobilized, which eliminates the need to review the distilled water levels and fill them throughout its useful life, making it 100% maintenance free. Additionally, this chemical composition tolerates continuous deep discharge cycles much more efficiently, offering greater durability before the daily consumption of an isolated solar installation.
- Why is it beneficial to include M8 copper plane terminals instead of the usual conical terminals? Copper has an electrical conductivity much higher than that of conventional lead. By having M8 copper flat terminals, the internal resistance is minimized at the point of contact, drastically reducing voltage falls and risks of overheating overhead current. In addition, it allows you to connect the eye terminals of your cables with direct bolts, achieving a perfect mechanical fixation that does not loosen.
- How long can the Victron Gel v220g without losing its effectiveness? Thanks to the use of high purity lead-acid-based grilles, this model exhibits an exceptionally low self-discharge rate. This means that it can remain stored or with the weekend housing system off for several months in a row without suffering deep sulfation, keeping its capacity intact by the time the loading system is reactivated.
- Is it totally safe to install this battery inside a camperized vehicle or residential passenger? Yes, it is completely safe. Being a sealed film-regulated film battery (VRLA), the gases produced during the loading process are automatically recombined inside. It does not produce emissions of harmful vapors or corrosive gases to the atmosphere, and lacking free liquid, it is immune to spills or leakage of acid, allowing its assembly in closed or inhabited spaces with total tranquility.
- What technical configuration precautions should be applied in the inverter charger for this gel monobloc? It is vital that you configure the load parameters of your regulator or your
in the specific profile for gel batteries. The voltage in the absorption phase must be strictly limited to the ranges stipulated by Victron (Generally between 14.1V and 14.4V for 12V systems) and any equalization function must be deactivated completely. Excessive overvoltage would cause the opening of VRLA valves, releasing gas and drying the gel irreversibly.inverter charger
- Battery Voltage (V)
- 12
- Ah
- 200 - 249