- Online only
SOLAR CHARGE CONTROLLER 20A STECA SOLARIX MPPT 2010 12V-24V
Solar charge controller Steca 20A from Solarix MPPT line with automatic adjustment to 12V or 24V systems. Highly efficient controller with maximum power point monitoring technology (MPPT), especially suitable for use with panels normally used for grid connection.
SOLAR CHARGE CONTROLLER 20A STECA SOLARIX MPPT 2010 12V-24V
The Steca regulators of the Solarix MPPT line have the latest technology to guarantee full power under all conditions of use, as well as optimal and professional care of the battery pack, all with a modern finish and outstanding protection functions.
The Steca Solarix MPPT 2010 model allows you to power the batteries with up to 20A of load current and the loads of consumption in DC with up to 10A.
|
Solarix MPPT 2010 |
Operating performance |
|
System voltage |
12 V (24 V) |
Nominal power |
250 W (500 W) |
Max. DC-DC efficiency |
> 98 % |
Own consumption |
10 mA |
DC input side |
|
MPP voltage |
15 V (30 V) < Vmodule<< 100 V |
Open circuit voltage solar module (at minimum operating temperature) |
**17 V ... 100 V (34 V … 100 V) |
Module current |
18 A |
DC output side |
|
Battery Charge current |
20 A |
Load current |
10 A |
End-of-charge voltage |
13,9 V (27,8 V)* |
Boost charge voltage |
14,4 V (28,8 V)* |
Equalisation charge |
14,7 V (29,4 V)* |
Reconnection voltage (LVR) |
12,5 V (25 V)* |
Deep discharge protection (LVD) |
11,5 V (23 V)* |
Operating conditions |
|
Ambient temperature |
-25 °C … +40 °C |
Fitting and construction |
|
Terminal (fine / single wire) |
16 mm2 / 25 mm2 - AWG 6 / 4 |
Degree of protection |
IP 32 |
Dimensions (X x Y x Z) |
187 x 153 x 68 mm |
Weight |
aprox. 900 g |
* see manual
**CAUTION: If an open circuit voltage of more than 75 V or 100 V is supplied to the connected solar module, the controller will be destroyed. When selecting the solarmodule, it is important to bear in mind that the open circuit voltage should never exceed 75 V or 100 V over the entire working temperature range. When using solar modules with a maximum open circuit voltage of between 60 and 100 V (over the entire temperature range), all installation steps must be carried in accordance with protection class II.