Single phase grid-connected photovoltaic inverter SMA 5000W AC. Solar inverter, with 2 MPPT, 96.5% efficiency and 15A maximum input current, with convection cooling method. Ideal for residential 230 V nominal input grid connection solar installations.
The Sunny Boy line stands out for its variety of configurations, wide MPPT voltage range and its light and compact structure. Designed for long life with protection against shortcircuits, overloads and high temperatures, it will provide trouble-free operation in your solar installation over the years. Outstanding product for solar installations with an excellent price-quality ratio. The Sunny Boy does not include a transformer.It offers a IP65 protection degree. 2-year product warranty and CE certificate.
Technical Features
Model |
SunnyBoy5.0 |
Max. DC power |
7500 W |
Max. Input voltage |
600 V |
MPP voltagerange |
175 V to 500 V |
Rated input voltage |
365 V |
Min. Input voltage / initial input voltage |
100 V / 125 V |
Max. input current input A / input B |
15 A / 15 A |
Max. input current per string input A / input B |
15 A / 15 A |
Number of independent MPP inputs / strings per MPP input |
2 / A:2; B:2 |
Output (AC) |
|
Rated power (at 230 V, 50Hz) |
5000 W |
Max. apparent power AC |
5000 VA |
Nominal AC Voltage / range |
220 V, 230 V, 240 V / 180 V to 280 V |
AC power frequency / range |
50 Hz, 60 Hz / −5 Hz to +5 Hz |
Rated power frequency / rated grid voltage |
50 Hz / 230 V |
Max. output current |
22 A |
Power factor at rated power |
1 |
Adjustable displacement power factor |
0.8 overexcitedto 0.8 underexcited |
Feed-in phases / connection phases |
1 / 1 |
Max. Efficiency / European Efficiency |
97.0% / 96.5% |
Protective devices |
|
Input-side disconnection point |
● |
Ground fault monitoring / grid monitoring |
● / ● |
DC reverse polarity protection / AC short circuit current capability / galvanically isolated |
● / ● / - |
All-pole-sensitive residual-current monitoring unit |
● |
Protection class (as per IEC 62103) / overvoltage category (according to IEC 60664-1) |
I / III |
General Data |
|
Dimensions (W / H / D) |
435 mm / 470 mm / 176 mm (17.1 inches / 18.5 inches / 6.9 inches) |
Weight |
17.5 kg (38.5 lb) |
Operating temperature range |
‒25°C to +60°C (‒13°F to +140°F) |
Noise emission, typical |
25 dB(A) |
Self-consumption (at night) |
5.0 W |
Topology |
Transformerless |
Cooling method |
Convection |
Degree of protection (as per IEC 60529) |
IP65 |
Climatic category (as per IEC 60721-3-4) |
4K4H |
Max. permissible value for relative humidity (non-condensing) |
100% |
Equipment |
|
DC connection / AC connection |
SUNCLIX / AC connector |
Display via smartphone, tablet, laptop |
● |
Interfaces: WLAN, Speedwire / Webconnect |
● / ● |
Warranty: 5 / 10 / 15 years |
● / ○ / ○ |
Certificates and approvals (more available upon request) |
AS 4777.2, C10/11, CE, CEI 0-21, EN 50438, G59/3-4, G83/2-1, DIN EN 62109 / IEC 62109, NEN-EN50438, IE-EN50438, NT_Ley20.571, ÖVE/ÖNORM E 8001-4-712 & TOR D4, PPDS, PPC, RD1699, TR3.2.1, UTE C15-712, VDE-AR-N 4105, VDE0126-1-1, VFR 2014 |
Certificates and approvals (planned) |
DEWA, IEC 61727, IEC 62116, MEA, NBR16149, PEA, SI4777, TR3.2.2 |
Country availability of SMA Smart Connected |
AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK |
● Standard features ○ Optional features — Not available Data at nominal conditions Status: February 2017 1) 4825 W according to VDE-AR-N 4105 2) 4600 W / 4600 VA according to VDE-AR-N 4105 3) AS 4777: 21.7 A |
|
Typedesignation |
SB5.0-1AV-41 |
- Power (kW)
- 3 - 5.9
- Phase Type
- Single phase
- Max Current Input (A)
- 15 - 15.99