Three-phase solar inverter for self-consumption or grid connection of SMA 10000W AC with 2 MPPT with an efficiency of 98% and a maximum input current of 20 A per input with convection cooling. The Sunny Tripower line stands out for its variety of configurations, its wide MPPT voltage range and its light and compact structure.
Resistant to short circuits, overloads and high temperatures, it will provide trouble-free operation of your three-phase solar system for many years. Grid-connected inverter for solar installations with an excellent price/performance ratio. Does not include transformer and offers IP65 protection.
Product warranty of 5 years.
The Sunny Tripower family of solar inverters is characterized by the following features:
- - Light weight solar inverter (20.5 kg) which allows it to be operated by one person
- - Compact inverter design for a smaller footprint
- - Easy installation with Plug&Play system
- - Intelligent energy management and storage solutions can be added at any time
- - Can be combined with TS4-R components for module optimization
- - Use of surplus energy through dynamic active power limitation
- - Shade management with OptiTrac Global Peak or integrated TS4-R communication
Model |
Sunny Tripower 10.0 |
Max. DC power |
15000 W |
Max. Input voltage |
1000 V |
MPP voltagerange |
320 to 800 V |
Rated input voltage |
580V |
Min. Input voltage / initial input voltage |
125V / 150V |
Max. input current input A / input B |
20/ 12A |
Max. input current per string input A / input B |
30A / 18 A |
Number of independent MPP inputs / strings per MPP input |
2 / A:2; B:1 |
Rated power (at 230 V, 50Hz) |
10000 W |
Max. apparent power AC |
10000 VA |
Nominal tension AC |
3/N/PE; 220V / 380 V 3/N/PE; 230V / 400V 3/N/PE; 240 V / 415 V |
Tension range AC |
180 V to 280 V |
Net frequency AC / range |
50 Hz / 45 Hz to 55 Hz 60 Hz / 55 Hz to 65 Hz |
Max. output current |
3 x 12.1 A |
Power factor at rated power |
1 |
Adjustable displacement power factor |
+/- 0.8 |
Feed-in phases / connection phases |
3 / 3 |
Max. Efficiency / European Efficiency |
98.3% / 98% |
Protective devices |
|
Input-side disconnection point |
● |
Ground fault monitoring / grid monitoring |
● / ● |
DC reverse polarity protection / AC short circuit current capability / galvanically isolated |
● / ● / - |
All-pole-sensitive residual-current monitoring unit |
● |
Protection class (as per IEC 62103) / overvoltage category (according to IEC 60664-1) |
I / III |
General Data |
|
Dimensions (W / H / D) |
460 mm / 497 mm / 176 mm (18.1 inches / 19.6 inches / 6.9 inches) |
Weight |
20.5kg (45.2 lb) |
Operating temperature range |
‒25°C to +60°C (‒13°F to +140°F) |
Noise emission, typical |
30 dB(A) |
Self-consumption (at night) |
5.0 W |
Topology |
Transformerless |
Cooling method |
Convection |
Degree of protection (as per IEC 60529) |
IP65 |
Climatic category (as per IEC 60721-3-4) |
4K4H |
Max. permissible value for relative humidity (non-condensing) |
100% |
Equipment |
|
DC connection / AC connection |
SUNCLIX / AC connector |
Display via smartphone, tablet, laptop |
● |
Interfaces: WLAN, Ethernet/ RS485 |
● / ● / ● |
Warranty: 5 / 10 / 15 years |
● / ○ / ○ |
Certificates and approvals (more available upon request) |
AS 4777.2, C10/11, CE, CEI 0-21, EN 50438, G59/3-4, G83/2-1, DIN EN 62109 / IEC 62109, NEN-EN50438, ÖVE/ÖNORM E 8001-4-712 & TOR D4, PPC, PPDS, RD1699, SI4777, TR3.2.1, UTE C15-712, VDE-AR-N 4105, VDE0126-1-1, VFR 2014, RfG compliant |
Certificates and approvals (planned) |
DEWA, IEC 61727, IEC 62116, IE-EN50438, MEA, NBR16149, NT_Ley20.571, PEA, TR3.2.2 |
Country availability of SMA Smart Connected |
AU, AT, BE, CH, DE, ES, FR, IT, LU, NL, UK |
Type designation |
STP10.0-3AV-40 |
- Power (kW)
- 10 - 14.9
- Phase Type
- Three-phase
- Max Current Input (A)
- 20+