4.6 kW Kostal PICO MP-2 plus single-phase solar inverter for grid connection. This inverter has 2 MPPT's (Maximum Power Point Tracker) that can be used to connect solar power or optionally for high voltage batteries. This option is available with the use of Kostal Smart Energy Meter.
This solar inverter has a built-in solar power isolator, IP65 protection which allows it to be installed outdoors. It incorporates the Kostal Solar Portal monitoring system, delivers 99.8% efficiency and Kostal provides a 5 year warranty. Its new technology allows the monitoring of the solar installation 24 hours a day
The Kostal PICO MP-2 single-phase inverter family is flexible, easy to communicate with its different accessories and can be coupled with lithium batteries. The main advantages of the Kostal solar inverters of this series are:
- - They have 1 or 2 MPPT's - Each MPPTS can be used bi-directionally to either connect solar panels or high voltage batteries.
- - The use of an MPPT as battery input is possible thanks to KOSTAL Smart Energy Meter.
- - Wide range of MPPT (Maximum Power Point Tracking) with 97% efficiency
- - 97% high efficiency inverter
- - 24-hour monitoring of the solar inverter (also at night)
- - Solar inverter with 0 % feed-in capability
- - Data logger, display, inverter monitoring system integrated in the inverter
- - Access to the solar system via the Kostal Portal App
- - DC circuit breaker integrated in the solar inverter
- - IP65 which allows outdoor installation of the inverter.
Model |
PIKO MP plus 4.6-2 |
INPUT (DC) |
|
Max. power PV for array (Wp) |
6900W |
Max. DC Voltaje (V) |
750 |
Operation Nominal DC (V) |
360 |
Max. current input (A) per MPPT |
13 |
Max. current (A) per MPPT |
15 |
Range Voltaje MPPT (V) |
180-600 |
Start up Voltaje (V) |
75 |
Number of MPP |
2 |
Strings per MPP |
1 |
OUTPUT (AC) |
|
Nominal AC POWER (VA) |
4600 |
Max.POWER AC (VA) |
4600 |
Nominal AC (AC range de tension) (V) |
220/230/240 |
Nominal/range (Hz) |
50/60 |
Range of grid (V) |
185 / 276 |
Max. current AC (A) |
20 |
Desplazamiento del factor de potencia |
0.8 leading – 0.8 lagging |
THDi, ratio of power (%) |
<3 |
EFFICIENCY |
|
Effiency Euro (%) |
98% |
Efficiency Max. (%) |
97,5 |
PROTECCIONS |
|
Grounding |
YES |
Reverse polarity |
YES |
DC Switch |
YES |
SPD class |
I / III |
Safety |
IEC 62116, IEC 61727, IEC 61683, IEC 60068(1,2,14,30), IEC 62109-1/2 |
EMC |
EN61000-6-1; EN61000-6-3; EN61000-3-2; EN61000-3-3; EN61000-3-11; EN61000-3-12 |
Grid Standards |
AS 4777, VDE V 124-1 0 V 0 0 , VDE V 0126-1-1, VDE-AR-N 4105, G83/2, C10/11, RD 1699 |
OTHER |
|
Degree of protection |
IP65 |
Temperature Range (ºC) |
-25; +60 |
Max. altitude (m) |
<2000 |
Humidity (%) |
0-100 (non-condensation) |
Storage Temp (ºC) |
-25; +60 |
Noise (dB) |
<25 |
DIMMENSIONS |
|
Dimensions (WxHxD) (mm) |
657 x 222 x 399 mm |
Weight (Kg) |
14 |
Ventilation |
Natural |
Tipology |
Non-isolated |
Comms interface |
RS485, WiFi/Ethernet (RJ45) |
LCD display |
Yes |
Warranty (years) |
5-10 |
- Power (kW)
- 3 - 5.9
- Phase Type
- Single phase
- Max Current Input (A)
- 13 - 13.99
- Compatibility list
- BYD HVS / HVM