- On sale!
580Sma Sunny Boy 1.5 - Inverter of network connection of 1500W
One of the inverters Photovoltaic small power best-selling in the world. The Sunny Boy series SMA, German leadership manufacturer, is characterized by high reliability, ease of assembly, scalability and maximum guarantees at a very competitive price.
The Sunny Boy is a inverter photovoltaic without transformer that transforms the direct current of the photovoltaic generator into alternating current suitable for the network and injects it into the public network.
For its low power, it allows to be used in self-consumption photovoltaic installations for direct use of generated energy.
The product is appropriate for use outdoors and interiors.
The Sunny Boy 1.5 model allows the connection of up to 1,600 W of photovoltaic solar to generate a power of 1,500 W in alternating current ready for use in the internal home of the house where it is installed.
| Technical data | Sunny Boy 1.5 | Sunny Boy 2.5 |
| Entrance (CC) | ||
| CC power max. (at cos φ = 1) | 1600 W | 2650 W |
| Max input voltage. | 600 V | 600 V |
| Voltage range of the MPP | 160 V at 500 V | 260 V at 500 V |
| Assigned entry voltage | 360 V | 360 V |
| Input voltage min. / Start | 50 V / 80 V | 50 V / 80 V |
| Max. entrance | 10 a | 10 a |
| Max. input by string | 10 a | 10 a |
| Number of independent MPP / Strings entries per input from MPP | 1/1 | 1/1 |
| Departure (CA) | ||
| Assigned power (at 230 V, 50 Hz) | 1500 W | 2500 W |
| Max power apparent | 1500 VA | 2500 VA |
| Nominal AC voltage | 220 V / 230 V / 240 V | 220 V / 230 V / 240 V |
| Nominal voltage range of AC | 180 V to 280 V | 180 V to 280 V |
| AC network frequency / range | 50 Hz, 60 Hz / -5 Hz A +5 Hz | 50 Hz, 60 Hz / -5 Hz A +5 Hz |
| Frequency / voltage assigned network | 50 Hz / 230 V | 50 Hz / 230 V |
| Max. outgoing | 7 a | 11 a |
| Power factor with assigned power | 1 | 1 |
| Adjustable lag factor | 0.8 inductive to 0.8 capacitive | |
| Injection phases / connection | 1/1 1/1 | |
| Performance | ||
| Max. / European Performance | 97,2% / 96,1% | 97,2% / 96,7% |
| Protective devices | ||
| Point of disconnection on the DC side | ● | ● |
| Earth / network monitoring | ● / ● | ● / ● |
| CC reverse polarization protection / AC short resistance / galvanic separation | ● / ● / - | ● / ● / - |
| Follow-up unit of the residual current sensitive to the universal current | ● | ● |
| Protection class (according to IEC 62103) / Overvoltage category (according to IEC 60664-1) | I / III | I / III |
| Reverse current protection | It is not necessary. | It is not necessary. |
| General data | ||
| Dimensions (wide x high x background) | 460/357/122 mm (18.1 / 14.1 / 4.8 in) | |
| Weight | 9.2 kg (20.3 lbs) | |
| Service temperature range | -40 ° C to +60 ° C (-40 ° F A +140 ° F) | |
| Typical noise emissions | ||
| Night self-consumption | 2.0 W | 2.0 W |
| Topology | Transformer | Transformer |
| Refrigeration system | Convection | Convection |
| Type of protection (according to IEC 60529) | Ip65 | Ip65 |
| Climate class (according to IEC 60721-3-4) | 4k4h | 4k4h |
| Maximum value allowed for relative humidity (without condensation) | 100% | 100% |
| Equipment | ||
| Connection of CC / CA | Sunclix / connector | Sunclix / connector |
| Screen | - | - |
| Interfaces: RS485, Bluetooth®, Speedwire / WebConnect, WLAN | - / - / ● / ● | - / - / ● / ● |
| Integrated Web Server | ● | ● |
| Warranty: 5/10/15/20/25 | ● / ○ / ○ / ○ / ○ | ● / ○ / ○ / ○ / ○ |
| Certificates and Authorizations (Others on request) | AS4777.3, C10 / 11/2012, CEI0-21Int, EN50438, G83 / 2, IEC61727, IEC62116, IEC62109, NBR16149, NEN- EN50438, NRS097-2-1, VDE-AR-N4105, VDE 0126-1-1, VFR2014 |
|
| Commercial model | SB 1.5-1VL-40 | SB 2.5-1VL-40 |
- Power (kW)
- 0.5 - 0.9
- Phase Type
- Single phase
- Max Current Input (A)
- 10-10.99