Single phase grid-connected photovoltaic inverter GW-2000-XS, 2000W AC, with 1 MPPT, 97,5% efficiency and 10 A maximum input current, with convection cooling method. Ideal for residential 230 V nominal input grid connection installations.
The GoodWE inverter line stands out for its variety of configurations, wide MPPT voltage range and its light and compact structure. Designed for long life with protection against shortcircuits, overloads and high temperatures, it will provide trouble-free operation in your solar installation over the years. Outstanding product for solar installations with an excellent price-quality ratio. Transformer-less technology .It offers an IP65 protection degree. 2-year product warranty and CE certificate.
In the following link you may see the accessories supplied with the product: https://drive.google.com/file/d/1Ff2LdriFav_-nDAu3yWzJ746g6_ACbiQ/view?usp=sharing.
Technical Features solar inverter
Model |
GW-2000-XS |
Input (DC) |
|
Max. DC power |
2600 W |
Max. Input voltage |
500 V |
MPP voltagerange |
50 V to450 V |
Rated input voltage |
360 V |
Min. Input voltage |
50 V |
Max. input current input |
12,5 A |
Max. short-circuit current per string |
15,6 A |
Number of independent MPPT inputs / strings per MPPT input |
1 / 1 |
Output (AC) |
|
Rated power (at 230 V, 50Hz) |
2000 W |
Max. apparent power AC |
2200 VA |
Nominal AC Voltage |
220 V, 230 V, 240 V |
AC power frequency |
50 Hz, 60 Hz |
Rated power frequency / rated grid voltage |
50 Hz / 230 V |
Max. output current |
9,6 A |
Power factor at rated power |
1 |
Adjustable displacement power factor |
0.8 overexcited to 0.8 underexcited |
Max. Efficiency / European Efficiency |
97.5% / 97.0% |
Protective devices |
|
Protection against islanding operation |
Integrated |
DC reverse polarity protection |
Integrated |
Insulation resistance protection |
Integrated |
Residual-current monitoring unit |
Integrated |
AC Over current protection |
Integrated |
AC short circuit current protection |
Integrated |
AC overvoltage protection |
Integrated |
General Data |
|
Dimensions (W / H / D) |
295 mm / 230 mm / 113 mm |
Weight |
5,8 kg |
Operating temperature range |
‒25°C to +60°C |
Noise emission, typical |
<25 dB(A) |
Self-consumption (at night) |
<1.0 W |
Topology |
Transformerless |
Cooling method |
Convection |
Degree of protection (as per IEC 60529) |
IP65 |
Max. permissible value for relative humidity (non-condensing) |
100% |
Equipment |
|
User Interface |
LCD & LED |
Communication protocols |
RS485 o WIFI |
GridconnectedStandards |
VDE0126-1-1, AS4777.2, EN50438(PL), G83, ERDF-NOI-RES_13E, IEC61727, IEC62116, CEI 0-21, RD 1699:2011 , UNE 206006 IN: 2011 , UNE 206007-1 IN: 2013 |
Safety Standards |
IEC62109-1&2 |
EMC |
EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4 |
- Power (kW)
- 0.5 - 0.9
- Phase Type
- Single phase
- Max Current Input (A)
- 12 - 12.99