Check availability
H2-6k-T2 three-phase solar energy storage inverters are used in residential PV energy storage systems, with peak cutting and valley filling functions to maximize the use of PV power generation. It has 2 MPPTs with a maximum current of 15A. I was able to connect up to 9kW of power from panels.
This achieves the objective of saving on residential electricity bills. In addition, different working modes can be configured according to different consumption needs. The investors SAJ 6 kW H2 can provide uninterrupted power for major charging devices with a backup power supply.
The SAJ H2 6KW 2MPPT 48V is a inverter a hybrid with 2 MPPTs to connect 1 string each, with a maximum input current of 15A/15A, with a working voltage per MPPT between 180 and 900V. This efficient inverter, allows easy installation in both residential and industrial areas, without a transformer and support for wall mounting.
In addition, it has integrated various protections such as AC short circuit, overload, DC overvoltage, overfrequency. Among its features, it has an LCD screen and communicates via Wi-Fi, GPRS and Ethernet.
- - Easy setup for intelligent working modes
- - Compatible with high intensity modules (up to 15A)
- - Supports 100% of three-phase line imbalance
- - Supports quick charging and discharging of battery
Model |
SAJ H2 6kW 2MPPT 48V |
INPUT (DC) |
|
Max, please. pV power per array (Wp)
|
9000
|
Max, please. DC voltage (V) |
1000 |
Nominal DC operating voltage (V) |
600 |
Max, please. input intensity (A) by MPPT |
15/15 |
Max, please. the measurements shall be carried out in accordance with the requirements set out in Annex II |
18/18 |
The voltage range MPPT (V) |
180-900 |
Operating starting voltage (V) |
180 |
Number of MPPT followers |
2 |
Strings by follower MPPT |
1 |
OUTPUT (AC) |
|
AC Nominal Power (VA) |
6000
|
Max, please. aC power (VA) |
6600 |
Rated network voltage (AC voltage range) (V) |
220, 230, 240 |
Rated network frequency/range (Hz) |
50/60 |
Network range (V) |
380/400 |
Max, please. Power supply |
10 |
Power factor shift |
0.8 leading – 0.8 lagging |
The test shall be carried out in accordance with the requirements of this Regulation |
Other |
EFFICIENCY |
|
Efficiency Euro (%) |
97.6 |
Efficiency Max. (%) |
98 |
PROTECTIONS |
|
Grounded protection |
YES , IT IS |
Reverse polarity protection |
YES , IT IS |
DC Switch |
YES , IT IS |
ENVIRONMENTAL LIMITS |
|
Protection degree (based on IEC 60529) |
IP65 |
Operating temperature range (oC) |
-40; +60 |
Max. operating altitude (m) |
< 4000 |
Humidity (%) |
0-100 (not condensed) |
Storage temperature (oC) |
-30; +60 |
Typical noise emission (dB) |
< 30 |
DIMENSIONS AND WEIGHT |
|
For the purposes of this Regulation, the following definitions shall apply: |
433*549*207 |
Weight (kg) |
25 |
Type of ventilation |
Natural |
Typology |
With no transformer |
Communication interface |
IT CAN / RS485 / DRM / RS232 |
LCD display |
LED + APP |
Standard Warranty (years) |
5 /10/15/20 |
- Power (kW)
- 6 - 9.9
- Short Circuit Current Isc (A)
- 17 - 17.99
- Phase Type
- Three-phase
- Max Current Input (A)
- 15 - 15.99