Check availability
Three phase inverter SAJ 33000W with 3 MPPT, a maximum efficiency of 98.8% and a maximum input current of 32A. These investors stand out for their safety, intelligence and efficiency.
The R6 series is a inverter three-phase grid connected for residential and commercial rooftop installations. They have a new industrial aesthetic design, with a wide LED inside the light ring to highlight key information. The 16A DC input current and the AFCI function (optional) make the R6 series a competitive product on the market. It is worth mentioning that this investor group supports 24-hour load monitoring, zero injection and commercial monitoring solutions for smart energy management.
Guarantee of 5 years (extendable).
The R6 series are characterised by the following features:
- - Max. PV input current 16A, better to match the mainstream PV modules on the market.
- - Smartly detect the arc signal on the DC side & cut off the power to prevent fire for a safer operation.
- - Max. Efficiency 98.8% 150% oversizing & 110% AC overloading.
- - IP65 protection (outdoor and indoor mounting)
- - WiFi included, USB connector and Plug & Play AC connector.
- - No fan available
- - Optional non-injection system.
System overview:
Datasheet:
Model
|
R6-33K-T3-32
|
Input (DC)
|
|
Max. PV Array Power [Wp]
|
59500
|
Max. Input Voltage [V]
|
1100
|
MPP Voltage Range [V]
|
180-1000
|
Nominal Input Voltage [V]
|
600
|
Start-up Voltage [V]
|
200
|
Max. Input Current [A]
|
32/32/32
|
Max. Short-Circuit Current[A]
|
38.4/38.4/38.4
|
Number of MPP Trackers
|
3
|
Number of Strings per MPP Tracker
|
2/2/2
|
Output (AC)
|
|
Rated AC Output Power [W]
|
33000
|
Max. AC Output Power [VA]
|
36300
|
Rated AC Output Current [A]
|
47.8
|
Max. AC Output Current [A]
|
55
|
Nominal AC Voltage/ Range [V]
|
3L+N+PE, 220/380, 230/400, 240/415; 180-280/312-485
|
Nominal AC Grid Frequency/ Range [Hz]
|
50, 60/44-55, 54-65
|
Total Distortion Harmonic [THDi]
|
< 3%
|
Power Factor
|
0.8 leading~0.8 lagging
|
Feed-in Phases/AC Connection Phases
|
3/3
|
Efficiency
|
|
Max. Efficiency
|
98.8%
|
Euro Efficiency
|
98.5%
|
Protection
|
|
DCI Monitoring
|
Integrated
|
GFCI Monitoring
|
Integrated
|
Grid Monitoring
|
Integrated
|
AC Grounding Detection
|
Integrated
|
AC Short-Circuit Protection
|
Integrated
|
DC Insulation Resistance Detection
|
Integrated
|
DC Surge Protection
|
Type II
|
AC Surge Protection
|
Type III
|
Anti-islanding Protection
|
AFD
|
AFCI Protection
|
Optional
|
Interface
|
|
AC Connection
|
Terminal Block
|
DC Connection
|
MC4
|
Display
|
LED+APP (Bluetooth)
|
Communication Port
|
RS232(USB)+RS485(RJ45)+DRM(RJ45)
|
Communication Mode
|
Wi-Fi/Ethernet/4G
|
Load Monitoring
|
24/7 (Optional)
|
General Data
|
|
Topology
|
Transformerless
|
Operating Temperature Range
|
-40℃~+60℃
|
Cooling Method
|
intelligent fan Cooling 0%~100% non-condensing
|
Noise [dBA]
|
<50
|
Dimensions [H*W*D] [mm]
|
473*659.4*240
|
Weight [kg]
|
35.5
|
Certifications
|
IEC/EN62109-1/2, EN61000-6-1/2/3/4, IEC61683, IEC60068-2, IEC62116, IEC61727, PEA/MEA, VDE0126-1-1/A1, CEI 0-21, VDE-AR-N 4105, AS/NZS4777.2, CQC NB/T 32004, G98/G99, NBR 16149, NBR 16150, C10/11, RD1669, UNE206006, UNE206007, EN50438
|
- Power (kW)
- + 30
- Phase Type
- Three-phase
- Max Current Input (A)
- 20+