SolarEdge 25000W three-phase inverter with SetApp configuration. It has an efficiency of 98% and a maximum input current of 36,325 A. This group of inverters stands out for its high power, lightness and efficiency.
The inverter maximises solar energy harvesting by combining digital control technology with an efficient power conversion architecture. The fixed voltage technology ensures that the inverter is always operating at an optimal input voltage, regardless of the number of modules in a string or environmental conditions. Inverter monitoring receiver data and power optimiser performance data from each solar array can be transmitted to the web.
12-25 year warranty.
SolarEdge SE three-phase solar inverters are characterised by the following features:
- - Fixed voltage inverter for superior efficiency (98.3%) and longer strings
- - Built in module level monitoring with Ethernet, wireless or cellular communication for full system visibility
- - Quick and easy inverter commissioning directly from a smartphone using the SolarEdge SetApp
- - Advanced safety features – integrated arc fault protection and optional rapid shutdown
- - Small, lightest in class, and easy to install
- - IP65 Outdoor and indoor installation
- - Integrated type 2 DC Surge Protection, to better withstand lightning events
- - Future-ready for SolarEdge energy storage solution
Datasheet:
Model
|
SE25K
|
OUTPUT
|
|
Rated AC Power Output
|
25000W
|
Maximum AC Power Output
|
25000VA
|
AC Output Voltage (Nominal)
|
380 / 220 ; 400 / 230 Vac
|
AC Output Voltage Range
|
304 – 437 / 176 – 253 ; 320 – 460 / 184 - 264.5 Vac
|
AC Frequency (Nominal)
|
50/60 ± 5 Hz
|
Maximum Continuous Output Current
|
36.25 A
|
AC Output Line Connections
|
3W + PE, 4W + PE
|
Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds
|
Yes
|
INPUT
|
|
Maximum DC Power
|
37500 W
|
Transformer-less, Ungrounded
|
Yes
|
Maximum Input Voltage
|
1000 Vdc
|
Nominal DC Input Voltage
|
750 Vdc
|
Maximum Input Current
|
36.25 Adc
|
Reverse-Polarity Protection
|
Yes
|
Ground-Fault Isolation Detection
|
167 kΩ Sensitivity
|
Maximum Inverter Efficiency
|
98.3 %
|
European Weighted Efficiency
|
98 %
|
STANDARD COMPLIANCE
|
|
Safety
|
IEC-62109, AS3100
|
Grid Connection Standards
|
VDE-AR-N-4105,G99,G99 (NI),AS-4777,EN50438,EN50438,CEI-021,VDE 0126-1-1,CEI-016, EN50549-1, EN50549-2,VDE-AR-N4110,TOR Erzeuger Typ,VFR 2019
|
Emissions
|
IEC61000-6-2, IEC61000-6-3 Class A, IEC61000-3-11, IEC61000-3-12
|
INSTALLATION SPECIFICATIONS
|
|
AC Output Gland Diameter / Wire Cross Section
|
Cable diameter 19-28 mm / 4 - 16 mm2
|
DC Input (PV)
|
4 MC4 pairs
|
Dimensions (H x W x D)
|
550 x 317 x 273 mm
|
Noise
|
< 62 dBA
|
Weight
|
32 kg
|
Cooling
|
Fan (user replaceable)
|
Operating Temperature Range
|
-40 to +60 C
|
Protection Rating
|
IP65 — Outdoor and Indoor
|
- Power (kW)
- 20 - 29.9
- Phase Type
- Three-phase
- Max Current Input (A)
- 20+