The PVSTAR PVS-AT12K-G2 PRO is the inverter Most powerful three-phase hybrid of the series, designed to offer exceptional performance in large-scale residential facilities and small businesses. With a nominal output of 12 kW, this equipment allows a Overview of entry DC up to 150% (18,000 WP), Maximizing solar uptake.
PVSTAR PVS-AT12K-G2 PRO: Maximum power for energy independence
The inverter PVS-AT12K-G2 PRO It is the PVSTAR flagship unit for three-phase systems. It has been developed to manage large photovoltaic fields and storage systems with millimeter precision, ensuring that each generated watt takes advantage of the most efficient way possible.
Key advantages of the Inverter PVS-AT12K-G2 PRO
-
Superior entry capacity: Allows you to connect up 18 kWp In solar panels, which ensures a fast battery charge and direct supply even under adverse weather conditions.
-
Intelligent phase management: Its ability to manage a 100% imbalance between phases It is vital in homes with mixed three-phase and single-phase loads, avoiding unnecessary network consumption in phases with low demand.
-
World Class Safety: Equipped with protection against Type II CC surges, Detection of insulation resistance and residual current monitoring, complying with the strictest global regulations.
-
Connectivity and control: The start-up is done in minutes through the PVSTAR App, allowing to configure custom operating modes such as "Time of Use" or "Backup Priority".
Technical characteristics (model 12k-g2 Pro)
-
Nominal output power: 12,000 W.
-
Maximum photovoltaic power: 18,000 WP.
-
MPPT number: 2 followers with entry current from 16 to each.
-
MPPT voltage range: 180 V - 950 V.
-
European efficiency: 97.9% (maximum 98.4%).
-
Degree of protection: Ip66 (Suitable for total exterior).
-
Dimensions: 545 x 465 x 205 mm.
-
Weight: 26 kg
-
Noise: Silent performance by natural cooling.
Frequently Asked Questions (FAQ)
- What kind of batteries can I connect to this inverter? The PVS-AT12K-G2 PRO is designed to work with high voltage lithium batteries, offering a fluid CAN / RS485 communication for optimized load management.
- Are you able to keep all my house running during a blackout? Yes, as long as the sum of the critical loads does not exceed the 12 kW nominal. Your response time It is so fast that most of the teams will not notice the cut.
- Why is the entry current of 16 A? Modern high-power panels (182mm / 210mm cells) generate more common. Many investors limit this entry to 11 a.m. or 13 A, losing energy; The PVSTAR Pro model takes 100% capacity.
- Does the refrigeration system require maintenance? No. When using refrigeration by natural convection, it has no fans that are clogged with dust or requiring substitution, which increases the useful life of the equipment.
- Power (kW)
- 10 - 14.9
- Phase Type
- Three-phase
- MPPT
- 3
- Inverter Type
- Hybrid