• Online only
  • On sale!
Victron BlueSolar MPPT 100/50 Solar Controller
Victron BlueSolar MPPT 75/10 Solar Controller
Victron BlueSolar MPPT 100/50 Solar Controller
Victron BlueSolar MPPT 100/50 Solar Controller
Victron BlueSolar MPPT 100/50 Solar Controller
Victron BlueSolar MPPT 75/10 Solar Controller
Victron BlueSolar MPPT 100/50 Solar Controller
Victron BlueSolar MPPT 100/50 Solar Controller

MPPT load controller Victron BlueBlussolar 100/50 50A 12V / 24V

BS-MPPT-100/50
€146.41
Tax included

The Solar charging regulator Victron BlueBlueBlinking MPPT 100/50 is a high efficiency industrial electronic controller designed to optimize the photovoltaic performance in own consumption Isolated with automatic voltage detection for battery banks 12V and 24V. This robust device stands out technically by integrating a processor with algorithm of Ultrafast tracking of the maximum power point (MPPT) that it manages to extract up 30% more energy daily that conventional PWM controllers under variable cloud conditions, managing a Nominal load current of 50a and tolerating elevated photovoltaic powers up 700W in 12V systems and up 1400W in 24V systems. Your passive security architecture admits a 100V open circuit tension and one Strict short circuit intensity at the 60A entrance.

 

Victron BLUESOLAR MPPT 100/50: Maximum load power, ultra-fast algorithm and industrial robustness

The correct administration of the direct current generated by the photovoltaic modules is crucial to guarantee the autonomy of the isolated installations and preserve the chemical integrity of the accumulators. The regulator Victron BlueBlueBlinking MPPT 100/50 It is presented as an advanced technological solution, robust and high capacity, ideal to optimize second residences, telecommunications stations, pumping systems or projects of own consumption From medium scale that operate with demand and demand a control of millimeter and professional power.

Photovoltaic performance optimized by ultra-fast tracking

The main competitive advantage of this model versus conventional pulse modulation controllers (PWM) lies in the agility of its power electronics. Your processor executes an algorithm of Ultrafast tracking of the maximum power point (MPPT) That adapts into microseconds to light changes caused by passenger or partial shaded clouds. This response speed drastically decreases energy losses, managing to extract up to a 30% more electricity daily of the same field of solar panels.

The device has a mechanism of Automatic voltage detection, which allows you to identify by yourself if you are connected to a battery bank 12V or 24V. The dimensioning of the plant is extremely simple, admitting a nominal photovoltaic power up 700W when working on 12V networks and doubling their ability up to 1400W in 24V systems. If by thermal peaks or the effect of reflected radiation, the plates exceed these watts momentarily, the integrated software limits the output to the nominal maximum to shield the internal tracks without interrupting the operation. To mechanically secure the assembly of solar collectors on flat or inclined roofs, we suggest you review our catalog of of anodized aluminum.

Extreme Extreme Electric Safety and Expandable Connectivity

Unlike traditional teams that lack modern communication channels, BlueBlueBLOCK MPPT 100/50 includes a physical VE.Direct. This interface allows directly linking the regulator (using an optional complementary backpack) with a smartphone or a GX device of Victron To program the load algorithms according to the specifications of the battery manufacturer, review historical production and update the firmware. If you are looking for configuring a residential self-consumption system connected directly to the electrical distribution network to lower the daytime light invoice without physical storage, we have a section specialized in inverters networking.

The physical architecture of Victron BlueBlueBlinking MPPT 100/50 It is designed under strict passive safety standards. To avoid catastrophic breakdowns by electric arcs or surge, the input string must rigorously respect a 100V Open Circuit Tension (VOC) and a short circuit intensity (ISC) that does not exceed any concept 60a. The daily cycle starts automatedly when the voltage of the Photovoltaic is 5V above the actual battery voltage, and it is maintained by efficiently operating as long as a minimum 1V differential during sunlight is preserved.

Technical characteristics:

  • Battery voltage: Intelligent automatic detection for systems A 12V and 24V.

  • Nominal load current: 50a.

  • Photovoltaic power (FV) Maximum nominal:

    • In 12V configurations: 700w.

    • In 24V configurations: 1400w.

  • Maximum tension of open circuit (VOC): 100V DC.

  • Maximum short circuit intensity (ISC): 60a (Critical entry limit to avoid damage).

  • Boot margin: Top FV voltage in battery + 5V to start; and battery + 1V in work phase.

  • Serial communications: Physical VE.Direct For external monitoring (optional app).

  • Dimensions of the chassis: 130 mm wide x 186 mm high x 70 mm depth.

  • Net weight of the team: 1.3 kg.

  • Availability: In stock.

FAQ Section (Frequently Asked Questions)

1. What is the real difference between this MPPT BlueBlue controller and a classic PWM regulator?

The PWM regulator strength to solar panels To work at the same tension that the battery has, wasting the excess voltage of the panel. Instead, the MPPT algorithm of Victron adjust the voltage continuously and the current to always be at the point of maximum power, which allows you to take advantage of up to a 30% more energy Daily under cloudy skies.

2. What happens if I connect a power of Superior than recommended for my voltage?

The BlueBlueBLOCK MPPT 100/50 has a software self-protection system. If your photovoltaic field exceeds 700W A 12V or the 1400W to 24V, the regulator will not suffer damage or burn; it will simply cut the surplus and actively limit the load current to your Nominal.

3. Why is it essential that the short circuit intensity (ISC) of the Do not exceed the 60A?

The 60a They are the maximum physical limit of resistance that the terminals are supported and the internal electronics of the controller. If you connect a combination of Solar (for example, too many chains in parallel) that overpassed this amperage, the generated heat can melt the tracks of the circuit, damaging the equipment irreversibly.

4. What are the voltage conditions necessary for the team to start uploading in the morning?

To break the inertia and activate the loading process, the total tension produced by the chain of Solar should be obligatorily at least 5V superior to current voltage of your battery. Once the operation has started, the regulator will continue to operate stably as long as the solar voltage remains 1V above the battery.

5. How can I connect this regulator Victron 50A to my mobile phone?

Unlike the SmartSolar range, the series Bluesolar It does not include bluetooth native. To connect it to your mobile phone, you must use the Port VE.Direct Integrated and connect the optional accessory VE.Direct Bluetooth Smart Dongle. This will allow you to use the official VICTRONCONNECT app to configure the equipment and monitor production.